Research on external electric field distribution of post insulator;
支柱绝缘子表面电场分布特性研究
The failures analysis of post insulator and porcelain bushing and study of ultrasonic testing technique;
支柱绝缘子和瓷套失效分析及超声波检测工艺方法研究
Profiles of HVDC post insulator and bushing used in converter station was researched from three aspects including pollution accumulation,artificial pollution test and artificial rain flashover test.
从积污、人工污秽试验、人工雨闪试验3个方面对高压直流换流站直流支柱绝缘子和套管伞形结构进行了研究。
In this paper,the mechanism and factors of electrolytic corrosion is studied when support insulators are used in HVDC.
讨论了高压直流支柱绝缘子金属部件在污秽条件下的腐蚀机理和影响因素。
Verifying the bending resistance of support insulator is one of the key points in the design of switch gear for support type busbar, and it is also an importance factor on which the selection of equipment should be based This article made an analysis of the horizontal loading of support insulator and gave an actual example of verifying the bending resistance of support insulato
支柱绝缘子抗弯强度校验是支持式管母配电装置设计工作的要点之一 ,也是支柱绝缘子设备选型的重要依据。
This paper introduces the application of ultrasonic flaw detecting technology for support insulator.
介绍了孝感供电局支柱绝缘子超声波探伤的应用 ,结合该局氵刁东 2 2 0 k V变电站管母支柱绝缘子断裂的经过及处理情况 ,分析了事故发生的原因 ,提出了关于管母的安装、运行、设计、试验等方面的意
In spring haze day,the supporting insulator of 500 kV step-up substation in CLP Guangxi Fangchenggang Power Co.
文章分析了中电广西防城港电力有限公司500 kV升压站支柱绝缘子在春季雾霾天出现雾闪,严重影响机组稳定运行及系统安全问题,结合对其运行维护2年多的实践,总结了一定的经验,供同行参考。
This paper is based on the supporting insulators of ±800 kV dry-wave reactor,being used finite-element analysis,analyzed the internal forces of the structural under static.
以±800 kV干式平波电抗器支柱式绝缘子支撑结构为研究对象,采用有限元分析方法分析了静力作用下的结构内力,并重点分析了多遇地震作用下的结构内力和位移以及罕遇地震作用下的结构变形,最后对结构进行了抗震性能评估。
outdoor pedestal type post insulator
户外针式支柱绝缘子
anti-pollution solid-core post insulator
防污型实心支柱绝缘子
Fault Analysis of the 750 kV GIS Supporting Insulators
750kV GIS支柱绝缘子故障分析
AC Electric Characteristics of 110 kV Post Insulators Covered with Ice or Snow
110kV支柱绝缘子交流覆冰(雪)电气特性
Countermeasures of Post Insulator Flashing in 500kV Boost Station
500kV升压站支柱绝缘子污闪防治对策
Analysis of 220 kV Switch Post Insulator Breakdown Accident
220kV闸刀支柱绝缘子断裂原因分析
Study and Test of Electrolytic Corrosion for HVDC Support Insulator
高压直流支柱绝缘子电化学腐蚀试验研究
Detecting Breakage Defect of Post Insulator with Ultraviolet Imaging Method
紫外成像法检测支柱绝缘子的破损缺陷
DC pollution flashover and rain performance for composite post insulators at high altitudes
复合支柱绝缘子直流污闪与污雨闪性能的比较
Unmerited Installation Lead to the Fracturation of Sustentacular Insulator
管母金具不当导致支柱绝缘子断裂的原因分析
Some Discussion on Prevention and Control of Pollution Flashover Caused by Post Insulator in 500 kV Step-up Substation
关于500kV升压站支柱绝缘子污闪防治的探讨
DC Flashover Performance of ±800 kV Composite Post Insulator in High Altitude Area
高海拔地区±800kV复合支柱绝缘子直流污闪特性
Analysis of the Reasons for Post Insulator Fault Resulting from Improper Installation
安装不当导致支柱绝缘子断裂的原因分析
Study of DC Flashover Performance and Mechanism of a Cylindrical Ice Model and Post Insulators Covered-with Ice;
冰柱模型和支柱绝缘子覆冰直流闪络特性与机理研究
A new robot for hot-line sweeping of post insulators in substations is introduced.
介绍了一种新型带电清扫变电站支柱绝缘子的机器人。
DC pollution flashover and rain flashover performance for composite post insulators at high altitudes
复合支柱绝缘子在高海拔区直流污闪与污雨闪性能
Application Study of RTV-Coated Electric Porcelain Post Insulator in ±800 kV UHV Converter Station
涂覆RTV的电瓷支柱绝缘子在±800kV特高压换流站的应用研究
Outdoor antipollution-type solid-core post insulators of ceramic material
GB12744-1991耐污型户外棒形支柱瓷绝缘子