Derived in the paper are mathematical models of heat and mass transfer for parallel flow type and counterflow type closed wet cooling tower(CWCT).
建立了顺流式、逆流式闭式冷却塔(CWCT)热质交换的数学模型,采用四阶Runge-Kutta方法对一小型冷却塔进行了数值计算,并将计算结果与试验值进行了比较。
The temperature changing rules of counter and parallel flow, including phase changing flow are given after theoretical analysis using the principle of heat transfer.
运用传热学基本原理进行理论分析,得出了顺流及逆流的单相流流动以及含有相变过程的两相流流动温度沿程变化规律;归纳了冷热流体沿程温度变化曲线斜率的特点,证明逆流流动温度沿程变化曲线的凸凹形状取决于比热容和流量乘积的相对大小。
By the analysis and comparison between the parallel flow mode and the counter - flow mode used in heat exchangers of the R407C room air conditioner, the paper points out that counter -flow mode has a better performance of the heat transfer than that ot the parallel flow mode.
本文通过对R407C制冷剂房间空调器换热器分别采用顺流和逆流两种布置方式的定性、定量分析和比较,指出,采用逆流布置方式能够强化换热器的换热性能,而且,换热器排数越多,采用逆流布置方式也就更容易接近真正的纯逆流,换热能力提高的幅度也就越大。
Model calculation and analysis of heat and mass transfer of air and water in a direct contact forward flow;
空气与水顺流直接接触热质交换过程模型计算及分析
A new technique that layer of carbon-bearing pellets is heated and direct reduced under conditon of parallel-flow heating with pre- heated air is put forword.
提出了一种顺流加热含碳球团直接还原的新方法。
Experimental study on microwave drying of thick layer brown rice with concurrent flow ventilation was carried out.
在顺流通风条件下厚层糙米的微波干燥实验结果表明 :增加微波功率 ,糙米的温度和干燥速度也会随之增加 ,但是糙米的爆腰率也会随之上升。
本网站所收集内容来自网友分享仅供参考,实际请以各学校实际公布信息为主!内容侵权及错误投诉:1553292129@qq.com
CopyRight © 2020-2024 优校网[www.youxiaow.com]版权所有 All Rights Reserved. ICP备案号:浙ICP备2024058711号